OEM:


ALFA ROMEO
9665523380
CITROËN
1920QK
CITROËN/PEUGEOT
1920QK
FIAT
9665523380
FORD
1514885 6C1Q9358AA 6C1Q9358AB
ISUZU
8980437350
LANCIA
9665523380
LAND ROVER
LR009837
MAZDA
RFY013V21 RFY013V21A
MITSUBISHI
1460A037
NISSAN
A6860EC09A A6860VM09A
PEUGEOT
1920QK

Cross-Reference Numbers

4X4 ESTANFI
LRE102028
A.Z. Meisterteile
AZMT-49-020-4301
ALFA ROMEO
9665523380
AUTLOG
AV6238
AUTOTEAM
L1093 L1093A2
BLUE PRINT
ADBP680017
BSG
BSG 30-155-004
CASALS
66044
CITROËN
1920QK
CITROËN/PEUGEOT
1920QK
CSV electronic parts
CVC3093 CVC3732
DENSO
DCRS300250 DCRS300260
DIPASPORT
INJDS003DPSN INJDS003N
DT Spare Parts
12.24228
ENGITECH
ENT230004 ENT230005 ENT230027/1
FEBI BILSTEIN
198054
FIAT
9665523380
FISPA
81.093 81.093A2 81.732
FORD
1514885 6C1Q9358AA 6C1Q9358AB
GMW
OG1920QK
HOFFER
8029207 8029207E 8029742
INTERMOTOR
89578
ISUZU
8980437350
JPN
75E1146-JPN
LANCIA
9665523380
LAND ROVER
LR009837
LEMARK
LDV041
MAGNETI MARELLI
215820002200
MAXGEAR
15-0009
MAZDA
RFY013V21 RFY013V21A
MDR
MEV-9102
MEAT & DORIA
9207 9207E 9742
MEC-DIESEL
34030246 340435 340435M
METZGER AUTOTEILE
0899414
MITSUBISHI
1460A037
MTR
12109309 DCRS300260
NISSAN
A6860EC09A A6860VM09A
NPS
M563A02
NTY
ESCV-MS-000 ESCV-NS-000
OSSCA
24951
PATRON
PRP012
PEUGEOT
1920QK
RECOFICIAL
CVC3093
RIDEX
1214C0002
RUFRE
RF-DCRS300250 RF-DCRS300260
SIDAT
81.093 81.093A2 81.732
Stark
SKCVF-4770001
TDM
DENDCRS300250 DENDCRS300260
VEMO
V22-11-0010
WE PARTS
392000046 392000047 392000114 392000223
WILMINK GROUP
WG1013417 WG1460931 WG1460932 WG1899347
YSPARTS
PCV192
ZZVF
ZV1514


Car Model:
CITROËN
FIAT
FORD
LAND ROVER
MITSUBISHI
NISSAN
OPEL
PEUGEOT
SUBARU


Follow us:
  • Introduction
  • Product Encyclopedia

Private label:Support

Warranty:12 Months

Packing:Natural Box or Color Box


Suits for Pump/Rail Number:



 Quality Assurance: Fuel Pump SCV Valve Testing

We are committed to excellence. Every Fuel Pump SCV Valve spare part undergoes rigorous testing for electrical integrity, precision, thermal stability, voltage tolerance, and durability across diverse operational environments.

 

Operational Excellence: Fuel Pump SCV Valve Inspection

YARN inspection protocol leverages a multi-layered approach, including full, random, and batch inspections. By utilizing diverse, high-end test benches to validate each unit at least twice times, we ensure peak performance. All assembly and testing are conducted in a state-of-the-art workshop.

 

Precision Engineering: Fuel Pump SCV Valve Installation

 When assembling the valve body and core, we adhere to strict technical tolerances. This precision-first approach ensures every control valve meets our high factory standards and delivers reliable, long-term value for our clients


FAQ:
Q1: Are you trading company or manufacturer?
A: We are factory in Rui an City.
Q2: How long is your production time?
A: Normal takes 3-7 days if we have stocks.If no enough stocks,it will takes about 20 days.
Q3: Do you provide samples? is it free or extra?
A: Yes.We offer samples.We charge for sample cost and freight cost.
Q4: What is your terms of payment?
A: Normal T/T payment.
Q5: What is your quality standard?
A: OE quality standard.All valves will test 2 times at least before shipment.Only ship the good quality.
Q6: Can you produce according to sample or customize product?
A: Yes. We have a professional technical team with pre-sale and after sale service to perform your request.
Q7: How do you make our business long-term and good relationship?
A: We keep good quality and competitive price to ensure our customers benefit ; We respect every customer as our friend and we sincerely do business and make friends with them.

Our Advantage:
Excellent Quality Stable and Reliable
1. stable supply chain.
2. Strong relationship with business partners.
3. 90% of the Chinese market, widely acclaimed.
4. Highly efficient team service.
5. Timely pre-sales and after-sales service.

Professional Factory Focus on product details:
1. Selected superior imported materials, mature material supply chain.
2. Strict production management according to IATF-16949.
3. Strict quality inspection, 200% quality inspection rate.
4. Exported to more than 30 countries and regions, trusted by customers.

Quality Warranty:
1 year quality guarantee, all products have been tested 2 times before leaving the factory to ensure stability.

Feedback:
Please share me video and photos to us for after sales.
We would also like to get your suggestions to improve our products.

If you have any questions or need a quotation, please feel free to contact us. We will reply to your email or phone call as soon as possible. We look forward to working with you to create a better future.

1. What Is a Fuel Pump Suction Control Valve

A fuel pump suction control valve (SCV) is an electrically actuated proportional valve installed at the inlet port of a high-pressure fuel pump, typically in diesel common rail systems. It regulates the volume of fuel drawn from the transfer pump (or tank) into the pumping chamber. The valve consists of a solenoid coil, an armature, a spring, and a variable orifice. When energized with a pulse-width modulated (PWM) signal from the engine control unit, the valve moves a plunger or spool to restrict or enlarge the inlet passage. By controlling how much fuel enters the pumping chamber, the SCV determines the output flow and thus the rail pressure. Unlike a pressure relief valve that dumps excess fuel after compression, the suction control valve meters fuel before compression, minimizing energy waste. Most modern common rail pumps (radial or inline piston pumps) use an SCV as the primary pressure control actuator. It operates at low suction side pressure (typically 2–10 bar) but directly influences the high-pressure output up to 2,500 bar.


2. Why the Fuel Pump Suction Control Valve Matters

The suction control valve is vital because it directly governs rail pressure accuracy, pump efficiency, and system durability. By admitting only the necessary fuel mass into the pumping chamber, it eliminates over-compression of excess fuel, reducing parasitic power loss by 3–7% compared to older systems with fixed inlet throttles. This lower pumping work translates into cooler fuel and longer component life. The SCV’s fast response (typically 5–15 ms) enables precise rail pressure control during rapid load changes, improving throttle response and reducing emissions spikes. Furthermore, the SCV acts as a safety component: most designs are normally open, so a loss of electrical signal allows maximum fuel flow, preventing fuel starvation and allowing limp‑home operation. Without a functioning SCV, the high-pressure pump would either deliver uncontrolled full flow (causing rail overpressure and injector damage) or no flow (engine stops). For these reasons, the SCV is indispensable for meeting modern emission regulations, achieving fuel economy targets, and ensuring reliable engine operation under all driving conditions.


3. Common Product Types by Fuel Pump Suction Control Valve

Suction control valves are classified by actuation principle, hydraulic characteristic, and application. Normally open (NO) is the most common type: with no current, the valve is fully open, allowing maximum fuel flow; increasing PWM duty cycle reduces flow. This provides fail‑safe operation (engine can still run, though pressure control is lost). Normally closed (NC) valves exist for some systems where fuel cut‑off on power loss is desired, but they are rarer. By internal design: poppet-type (a cone seats against an orifice) – simple and leak‑tight, used in lower-flow pumps; spool-type (a sliding spool with metering edges) – offers better linearity and higher flow capacity, common in high‑power engines. By control method: analog current‑controlled and PWM voltage‑controlled. Some advanced SCVs include a position sensor (inductive or Hall effect) for closed‑loop feedback, enabling more precise metering. By flow rating: low flow (up to 30 L/h for small passenger car pumps), medium (30–100 L/h), and high flow (>100 L/h for heavy‑duty trucks). Additionally, there are two‑stage SCVs that use a small pilot solenoid to control a larger main valve, reducing electrical power consumption while handling high flow rates.